Edge Aligner register mapΒΆ
Register Name |
Register offset |
Field name |
Field position |
Description |
---|---|---|---|---|
PERIOD |
0x0 |
period_value |
15:0 |
Value of the PWM period |
DEADTIME |
0x4 |
deadtime_value |
15:0 |
Value of the overall deadtime |
DUTY |
0X8 |
duty_value |
15:0 |
Value of the PWM duty cycle |
DTA_FACTOR |
0XC |
dta_factor |
15:0 |
Value of the dead time asymmetry correction factor |
MODULATOR_CTRL |
0x10 |
modulator_start |
0 |
Start PWM modulator |
modulator_stop |
1 |
Stop PWM modulator |
||
DUTY_SAT_L |
0x14 |
duty_sat_value |
15:0 |
Duty cycle saturation minimum value |
DUTY_SAT_H |
0x18 |
duty_sat_value |
15:0 |
Duty cycle saturation maximum value |
MODULATOR_SYNC |
0x1C |
sync |
0 |
Synchronize modulator carrier |
MODULATOR_SHIFT |
0x20 |
shift_value |
15:0 |
Value of the carrier shift for the PWM modulator |